Shanxay Mitsubishi Elevator elektr taxtasi sozlamalari bo'yicha keng qamrovli qo'llanma
Mundarija
1. Boshqaruv shkafi (203-modda) sozlamalari
1.1 P1 plata konfiguratsiyasi (Modellar: P203758B000/P203768B000)
1.1 Ishlash rejimini sozlash
Funktsiya holati | MON0 | MON1 | SET0 | SET1 |
---|---|---|---|---|
Oddiy operatsiya | 8 | 0 | 8 | 0 |
Nosozliklarni tuzatish/xizmat | Nosozliklarni tuzatish qo'llanmasiga rioya qiling |
1.2 Aloqa konfiguratsiyasi (Jumper qoidalari)
Lift turi | GCTL | GCTH | ELE.NO (Guruh nazorati) |
---|---|---|---|
Yagona lift | O'tmagan | O'tmagan | - |
Parallel/guruh | ● (O'tish) | ● (O'tish) | 1~4 (#F~#I liftlari uchun) |
2. Avtomobil yuqori stansiyasi (231-modda) Sozlamalar
2.1 Eshik boshqaruv paneli (Model: P231709B000)
2.2 Jumperning asosiy sozlamalari
Funktsiya | Jumper | Konfiguratsiya qoidasi |
---|---|---|
OLT signalini o'chirish | JOLT | Faqat CLT/OLT o'rnatilgan bo'lsa, jumper |
Old/orqa eshik | FRDR | Orqa eshiklar uchun jumper |
Dvigatel turini tanlash | IN THE | Asenkron motorlar uchun jumper (IM) |
2.3 Dvigatel yo'nalishi va parametrlari
Motor modeli bo'yicha | Dvigatel turi | FB Jumper |
---|---|---|
LV1-2SR/LV2-2SR | Asinxron | ● |
LV1-2SL | Sinxron | ● |
2.4 SP01-03 Jumper funksiyalari
Jumper guruhi | Funktsiya | Konfiguratsiya qoidasi |
---|---|---|
SP01-0,1 | Boshqarish rejimi | Har bir eshik motori modeliga o'rnatilgan |
SP01-2,3 | DLD sezgirligi | ●● (Standart) / ●○ (past) |
SP01-4,5 | JJ hajmi | Shartnoma parametrlariga rioya qiling |
SP02-6 | Dvigatel turi (faqat PM) | TYP=0 bo'lsa, o'tish |
2.5 JP1~JP5 uchun jumper sozlamalari
JP1 | JP2 | JP3 | JP4 | JP5 | |
1D1G | 1-2 | 1-2 | X | X | 1-2 |
1D2G/2D2G | X | X | 2-3 | 2-3 | 1-2 |
Eslatma: "1-2" mos keladigan o'tish pinlari 1 va 2; "2-3" mos keladigan o'tish pinlari 2 va 3 ni anglatadi
3. Avtomobilni ishlatish paneli (235-modda) sozlamalari
3.1 Tugma paneli (Model: P235711B000)
3.2 Tugmachalar joylashuvi konfiguratsiyasi
Tartib turi | Tugmalar soni | RSW0 sozlamasi | RSW1 sozlamasi |
---|---|---|---|
Vertikal | 2-16 | 2-F | 0-1 |
17-32 | 1-0 | 1-2 | |
Gorizontal | 2-32 | 0-F | 0 |
3.3 Jumper konfiguratsiyasi (J7/J11)
Panel turi | J7.1 | J7.2 | J7.4 | J11.1 | J11.2 | J11.4 |
---|---|---|---|---|---|---|
Old asosiy panel | ● | ● | - | ● | ● | - |
Orqa asosiy panel | ● | - | ● | ● | - | ● |
4. Qo'nish stantsiyasi (280-modda) sozlamalari
4.1 Uchish taxtasi (Model: P280704B000)
4.2 Jumper sozlamalari
Zamin holati | TERH | TERL |
---|---|---|
Pastki qavat (ekransiz) | ● | ● |
O'rta/yuqori qavatlar | - | - |
4.3 Qavat tugmalarini kodlash (SW1/SW2)
Tugma raqami | SW1 | SW2 | Tugma raqami | SW1 | SW2 |
---|---|---|---|---|---|
1-16 | 1-F | 0 | 33-48 | 1-F | 0-2 |
17-32 | 1-F | 1 | 49-64 | 1-F | 1-2 |
5. Qo'ng'iroq qilish (366-modda) sozlamalari
5.1 Tashqi qo'ng'iroqlar paneli (Modellar: P366714B000/P366718B000)
5.2 Jumper qoidalari
Funktsiya | Jumper | Konfiguratsiya qoidasi |
---|---|---|
Pastki qavatdagi aloqalar | OGOHLANTIRISH/MUMKIN | Har doim sakragan |
Zaminni sozlash | SET/J3 | O'rnatish vaqtida vaqtincha o'tish |
Orqa eshik konfiguratsiyasi | J2 | Orqa eshiklar uchun jumper |
6. Tanqidiy eslatmalar
6.1 Operatsion ko'rsatmalar
-
Birinchi navbatda xavfsizlik: Jumperni sozlashdan oldin har doim quvvatni uzing. CAT III 1000V izolyatsiyalangan asboblardan foydalaning.
-
Versiya nazorati: Oxirgi qoʻllanma (2023-yil avgust) yordamida tizimni yangilagandan soʻng sozlamalarni qayta tasdiqlang.
-
Muammolarni bartaraf qilish; nosozliklarni TUZATISH: "F1" yoki "E2" xato kodlari uchun bo'sh yoki noto'g'ri sozlangan jumperlarni tekshirishga ustuvor ahamiyat bering.
6.2 Strukturaviy ma'lumotlar taklifi
Texnik yordam: Tashrif buyuringwww.felevator.comyangilanishlar uchun yoki sertifikatlangan muhandislar bilan bog'laning.
Tasvirli eslatmalar:
-
Boshqaruv shkafi P1 taxtasi: GCTL/GCTH pozitsiyalarini, ELE.NO zonalarini va MON/SET aylanma kalitlarini ajratib ko'rsatish.
-
Eshikni boshqarish SP jumperlari: Rang kodining sezgirligi va vosita turi zonalari.
-
Avtomobil tugmachalari paneli: J7/J11 jumperlari va tugmalarni joylashtirish rejimlarini aniq belgilang.
-
Uchish taxtasi: TERH/TERL pozitsiyalari va SW1/SW2 qavat kodlash.
-
Qo'nishga qo'ng'iroq qilish paneli: CANH/CANL aloqa o'tish moslamalari va polni o'rnatish joylari.