Sirkuit Keamanan (SF)

4.1 Ringkesan

IngSirkuit Keamanan (SF)njamin kabeh piranti safety mechanical lan electrical operasional. Ngalangi operasi elevator yen ana kondisi safety sing dilanggar (contone, mbukak lawang, overspeed).

Komponen Kunci

  1. Rantai Aman (#29):

    • Saklar safety sing disambungake seri (contone, saklar pit, gubernur, mandeg darurat).

    • Powers relay safety#89(utawa logika internal ing papan P1 basa C).

  2. Sirkuit Kunci Pintu (#41DG):

    • Kunci lawang sing disambungake seri (mobil + lawang landing).

    • Powered by#78(output saka chain safety).

  3. Priksa Keamanan Zona Pintu:

    • Paralel karo kunci lawang. Aktifake mung nalika lawang mbukak ing zona kebangkrutan.

Fungsi Kritis:

  • Cut daya kanggo#5 (kontaktor utama)lan#LB (kontaktor rem)yen micu.

  • Dipantau liwat LED ing papan P1 (#29, #41DG, #89).


4.2 Langkah Ngatasi Masalah Umum

4.2.1 Identifikasi Fault

Gejala:

  • #29/#89 LED mati→ Rantai safety diselani.

  • Mandeg darurat→ Sirkuit safety dipicu nalika operasi.

  • Ora wiwitan→ Sirkuit safety mbukak nalika istirahat.

Metode Diagnostik:

  1. Indikator LED:

    • Priksa LED papan P1 (#29, #41DG) kanggo sirkuit mbukak.

  2. Kode Fault:

    • Contone, "E10" kanggo gangguan chain safety (kanggo fault transient).

4.2.2 Lokalisasi Fault

  1. Sirkuit Terbuka Stabil:

    • Gunakaketes adhedhasar zona: Ukur voltase ing titik persimpangan (contone, pit, ruang mesin).

    • Conto: Yen voltase mudhun ing antarane prapatan J10-J11, priksa switch ing zona kasebut.

  2. Sirkuit Terbuka Intermiten:

    • Ganti saklar sing curiga (contone, saklar pit sing rusak).

    • Tes bypass: Gunakake kabel serep kanggo nyambungake segmen kabel kanthi berlebihan (ora kalebu ngalih).

WARNING: Aja ngalih safety short-circuit kanggo testing.

4.2.3 Door Zone Safety Faults

Gejala:

  • Tiba-tiba mandheg nalika leveling maneh.

  • Kode fault related kanggo sinyal zona lawang (RLU / RLD).

Penyebab Root:

  1. Sensor Zona Pintu Misaligned (PAD):

    • Setel celah ing antarane PAD lan vane magnetik (biasane 5-10mm).

  2. Relay sing rusak:

    • Relay test (DZ1, DZ2, RZDO) ing papan perlindungan.

  3. Masalah Wiring Sinyal:

    • Priksa manawa kabel sing rusak / terlindung ing cedhak motor utawa kabel voltase dhuwur.


4.3 Kasalahan Umum & Solusi

4.3.1 #29 LED Mati (Safety Chain Open)

sabab Solusi
Bukak Ngalih Safety Ngalih tes kanthi urut (contone, gubernur, switch pit, stop darurat).
00S2 / 00S4 Sinyal Mundhut Verifikasi sambungan menyang400sinyal (kanggo model tartamtu).
Papan Safety Rusak Ganti papan W1 / R1 / P1 utawa panel inspeksi landing PCB.

4.3.2 #41DG LED Mati (Kunci Lawang Mbukak)

sabab Solusi
Kunci Pintu Rusak Priksa kunci lawang mobil/landing nganggo multimeter (uji kontinu).
Pisau Pintu Misaligned Setel celah piso-kanggo-roller (2–5mm).

4.3.3 Stop Darurat + Lampu Tombol Urip

sabab Solusi
Gangguan Kunci Pintu Priksa manawa mbukak kunci lawang nalika mlaku (contone, nganggo roller).

4.3.4 Stop Darurat + Lampu Tombol Pateni

sabab Solusi
Rantai Safety Micu Priksa switch pit kanggo impact karat/kabel; test overspeed gubernur.