Guide Comprehensive kanggo Shanghai Mitsubishi Elevator Papan Listrik Setelan
Daftar Isi
1. Kabinet Kontrol (Item 203) Setelan
1.1 Konfigurasi Papan P1 (Model: P203758B000/P203768B000)
1.1 Konfigurasi Mode Operasi
Status Fungsi | MON0 | MON1 | SET0 | SET1 |
---|---|---|---|---|
Operasi Normal | 8 | 0 | 8 | 0 |
Debug/Layanan | Tindakake manual debugging |
1.2 Konfigurasi Komunikasi (Aturan Jumper)
Tipe Lift | GCTL | GCTH | ELE.NO (Kontrol Grup) |
---|---|---|---|
Lift Tunggal | Ora mlumpat | Ora mlumpat | - |
Paralel / Kelompok | ● (Mlumpat) | ● (Mlumpat) | 1~4 (kanggo lift #F~#I) |
2. Mobil Top Station (Item 231) Setelan
2.1 Papan Kontrol Pintu (Model: P231709B000)
2.2 Setelan Jumper dhasar
Fungsi | Jumper | Aturan Konfigurasi |
---|---|---|
Sinyal OLT Pateni | JOLT | Jumper yen mung CLT / OLT diinstal |
Lawang Ngarep/Mburi | FRDR | Jumper kanggo lawang mburi |
Pilihan Tipe Motor | ING | Jumper kanggo motor asinkron (IM) |
2.3 Arah Motor & Parameter
Miturut Model Motor | Tipe Motor | FB Jumper |
---|---|---|
LV1-2SR/LV2-2SR | Asynchronous | ● |
LV1-2SL | Sinkron | ● |
2.4 SP01-03 Fungsi Jumper
Klompok Jumper | Fungsi | Aturan Konfigurasi |
---|---|---|
SP01-0,1 | Mode Kontrol | Setel saben model motor lawang |
SP01-2,3 | Sensitivitas DLD | ●● (Standar) / ●○ (Sedheng) |
SP01-4,5 | Ukuran JJ | Tindakake paramèter kontrak |
SP02-6 | Tipe Motor (PM only) | Jumper yen TYP=0 |
2.5 Setelan jumper kanggo JP1~JP5
JP1 | JP2 | JP3 | JP4 | JP5 | |
1D1G | 1-2 | 1-2 | X | X | 1-2 |
1D2G/2D2G | X | X | 2-3 | 2-3 | 1-2 |
Cathetan: "1-2" tegese pin jumper sing cocog 1 lan 2; "2-3" tegese pin jumper 2 lan 3 sing cocog
3. Panel Operasi Mobil (Item 235) Setelan
3.1 Papan Tombol (Model: P235711B000)
3.2 Konfigurasi Tata Letak Tombol
Tipe Tata Letak | Jumlah Tombol | Setelan RSW0 | Setelan RSW1 |
---|---|---|---|
Vertikal | 2-16 | 2-F | 0-1 |
17-32 | 1-0 | 1-2 | |
Horisontal | 2-32 | 0-F | 0 |
3.3 Konfigurasi Jumper (J7/J11)
Tipe Panel | J7.1 | J7.2 | J7.4 | J11.1 | J11.2 | J11.4 |
---|---|---|---|---|---|---|
Panel Utama ngarep | ● | ● | - | ● | ● | - |
Panel Utama mburi | ● | - | ● | ● | - | ● |
4. Landing Station (Item 280) Setelan
4.1 Papan Kebangkrutan (Model: P280704B000)
4.2 Setelan Jumper
Posisi Lantai | TERH | TERL |
---|---|---|
Lantai Ngisor (Ora Ana Tampilan) | ● | ● |
Lantai Tengah / Ndhuwur | - | - |
4.3 Pengkodean Tombol Lantai (SW1/SW2)
Nomer Tombol | SW1 | SW2 | Nomer Tombol | SW1 | SW2 |
---|---|---|---|---|---|
1-16 | 1-F | 0 | 33-48 | 1-F | 0-2 |
17-32 | 1-F | 1 | 49-64 | 1-F | 1-2 |
5. Telpon Landing (Item 366) Setelan
5.1 Papan Panggilan Eksternal (Model: P366714B000/P366718B000)
5.2 Aturan Jumper
Fungsi | Jumper | Aturan Konfigurasi |
---|---|---|
Lantai ngisor Comms | WARNING / BISA | Tansah mlumpat |
Persiyapan Lantai | SET / J3 | Jumper sementara sak persiyapan |
Konfigurasi Lawang mburi | J2 | Jumper kanggo lawang mburi |
6. Cathetan Kritis
6.1 Pedoman Operasional
-
Safety First: Tansah pedhot daya sadurunge pangaturan jumper. Gunakake alat terisolasi CAT III 1000V.
-
Kontrol versi: Revalidasi setelan sawise nganyarke sistem nggunakake manual paling anyar (Agustus 2023).
-
Ngatasi masalah: Kanggo kode kesalahan "F1" utawa "E2", prioritize mriksa jumper ngeculke utawa misconfigured.
6.2 Saran Data Terstruktur
Dhukungan Teknis: Dolan maringwww.felevator.comkanggo nganyari utawa hubungi engineers certified.
Cathetan Ilustrasi:
-
Kabinet Kontrol Papan P1: Sorot posisi GCTL/GCTH, zona ELE.NO, lan switch rotary MON/SET.
-
Kontrol Pintu SP Jumpers: Sensitivitas kode warna lan zona jinis motor.
-
Papan Tombol Mobil: Label J7 / J11 jumper cetha lan mode tata tombol.
-
Papan kebangkrutan: Posisi TERH / TERL lan enkoding lantai SW1 / SW2.
-
Papan Panggilan Landing: Jumper komunikasi CANH / CANL lan area persiyapan lantai.