Wiidweidige gids foar Shanghai Mitsubishi Elevator Electrical Board Ynstellings
Ynhâldsopjefte
1. Control Cabinet (Item 203) Ynstellings
1.1 P1 Board konfiguraasje (modellen: P203758B000/P203768B000)
1.1 Operating Mode Konfiguraasje
Funksje State | MOAN0 | MOAN1 | SET0 | SET1 |
---|---|---|---|---|
Normale operaasje | 8 | 0 | 8 | 0 |
Debug / tsjinst | Folgje debuggen hantlieding |
1.2 Kommunikaasjekonfiguraasje (Jumperregels)
Lift Type | GCTL | GCTH | ELE.NO (Groepskontrôle) |
---|---|---|---|
Single Elevator | Net sprongen | Net sprongen | - |
Parallel / Groep | ● (Skeppele) | ● (Skeppele) | 1~4 (foar #F~#I liften) |
2. Car Top Station (Item 231) Ynstellings
2.1 Door Control Board (Model: P231709B000)
2.2 Basis Jumper ynstellings
Funksje | Jumper | Konfiguraasje Rule |
---|---|---|
OLT-sinjaal útskeakelje | JOLT | Jumper as allinnich CLT / OLT is ynstallearre |
Foar- / efterdoar | FRDR | Jumper foar efterdoarren |
Motor Type Seleksje | IN DE | Jumper foar asynchrone motoren (IM) |
2.3 Motorrjochting & parameters
By Motor Model | Motor Type | FB Jumper |
---|---|---|
LV1-2SR/LV2-2SR | Asynchronous | ● |
LV1-2SL | Syngroane | ● |
2.4 SP01-03 Jumper funksjes
Jumper groep | Funksje | Konfiguraasje Rule |
---|---|---|
SP01-0,1 | Kontrôle modus | Set per doar motor model |
SP01-2,3 | DLD gefoelichheid | ●● (Standert) / ●○ (Leech) |
SP01-4,5 | JJ Grutte | Folgje kontrakt parameters |
SP02-6 | Motortype (allinich PM) | Jumper as TYP=0 |
2.5 Jumper ynstellings foar JP1 ~ JP5
JP1 | JP2 | JP3 | JP4 | JP5 | |
1D1G | 1-2 | 1-2 | X | X | 1-2 |
1D2G/2D2G | X | X | 2-3 | 2-3 | 1-2 |
Opmerking: "1-2" betsjut de oerienkommende jumper pins 1 en 2; "2-3" betsjut de oerienkommende jumper pins 2 en 3
3. Car Operating Panel (Item 235) Ynstellings
3.1 Button Board (Model: P235711B000)
3.2 Knop Layout Konfiguraasje
Layout Type | Knop Count | RSW0 ynstelling | RSW1 ynstelling |
---|---|---|---|
Fertikaal | 2-16 | 2-F | 0-1 |
17-32 | 1-0 | 1-2 | |
Horizontaal | 2-32 | 0-F | 0 |
3.3 Jumper konfiguraasjes (J7/J11)
Panel Type | J7.1 | J7.2 | J7.4 | J11.1 | J11.2 | J11.4 |
---|---|---|---|---|---|---|
Front Main Panel | ● | ● | - | ● | ● | - |
Rear Main Panel | ● | - | ● | ● | - | ● |
4. Landing Station (Item 280) Ynstellings
4.1 Landing Board (Model: P280704B000)
4.2 Jumper ynstellings
Floor Posysje | TERH | TERL |
---|---|---|
Underste ferdjipping (gjin werjefte) | ● | ● |
Middelste / boppeste ferdjippings | - | - |
4.3 Koaring fan flierknop (SW1/SW2)
Knop nûmer | SW1 | SW2 | Knop nûmer | SW1 | SW2 |
---|---|---|---|---|---|
1-16 | 1-F | 0 | 33-48 | 1-F | 0-2 |
17-32 | 1-F | 1 | 49-64 | 1-F | 1-2 |
5. Landing Call (Item 366) Ynstellings
5.1 External Call Board (modellen: P366714B000/P366718B000)
5.2 Jumper regels
Funksje | Jumper | Konfiguraasje Rule |
---|---|---|
Underste ferdjipping Comms | WARSKUWING / KINNE | Altyd jumper |
Floor Setup | SET/J3 | Jumper tydlik tidens opset |
Rear Door Config | J2 | Jumper foar efterdoarren |
6. Critical Notes
6.1 Operasjonele Rjochtlinen
-
Feiligens earst: Skeakelje altyd de stroom út foar oanpassingen fan jumper. Brûk CAT III 1000V isolearre ark.
-
Ferzje Control: Ynstellings opnij falidearje nei systeemupgrades mei de lêste hânlieding (augustus 2023).
-
Troubleshooting: Foar flater koades "F1" of "E2", prioriteit kontrolearjen losse of misconfigured jumpers.
6.2 Strukturearre Data Suggestie
Technyske stipe: besykjewww.felevator.comfoar updates of nim kontakt op mei sertifisearre yngenieurs.
Illustration Notes:
-
Control Cabinet P1 Board: Markearje GCTL / GCTH posysjes, ELE.NO sônes, en MON / SET draaiknoppen.
-
Door Control SP Jumpers: Kleur-koade gefoelichheid en motor type sônes.
-
Auto Button Board: Label J7 / J11 jumpers en knopopmaakmodi dúdlik.
-
Landing Board: TERH / TERL posysjes en SW1 / SW2 flier kodearring.
-
Landing Call Board: CANH / CANL kommunikaasje jumpers en ferdjipping opset gebieten.